Chillers

Efficient Cooling Technology The exclusive use of high-quality and internationally accepted and of the titanium heat exchanger, ensures high performance and low energy consumption. The set of technologies used allow you to achieve the highest COP - coefficient of performance and the lowest noise levels

  • TECO TK 15K commercial heat pump 3-phase chiller/heater Commercial Chiller Teco

    Teco TECO TK 15K commercial heat pump 3-phase chiller/heater

    The exclusive use of internationally recognized, high-performance rotary compressors and of the titanium heat exchanger, ensures high performance and low energy consumption. The set of technologies used allows you to decrease noise levels and achieve the highest COP - coefficient of performance - contributing to significant energy savings. Digital Thermostat he setting of functions is intuitive and the temperature detection is accurate, resolution 0.5°C/1°F. The setting range is 5°-40°C (41°F-104°F) and there is a closed loop temperature control system with high accuracy and extremely tight differential 2°C/5°F. Displayed temperature is in °C or °F and there are security alarms. Possibility to control remotely the display using supplied cable, degree of protection IPX4. Efficient Design The chiller is characterized by a solid structure, designed to provide a perfect oxidation protection and therefore perfect for use with salt water Unique Features These units are also suitable for industrial applications and outdoor installation. Vertical ventilation ensures optimal operation even when working in harsh environments. Water temp. Ambient temp. Working mode Cooling Capacity COP** 25°C* 38°C Cooling 14,6KW 2,1 * The values reported in the table refer to the following conditions: heating load of 0.5 w/lt.** Coefficient of performance Power Supply Power Consumption Gas Weight Ambient temperature 50Hz - 3ph 6890W R410A 286,6 lb 5°C - 38°C All data are approximate and may be changed without notice by TECO.

    £18,590.69

  • TECO TK 8K commercial heat pump 3-phase chiller/heater Commercial Chiller Teco

    Teco TECO TK 8K commercial heat pump 3-phase chiller/heater

    The exclusive use of internationally recognized, high-performance rotary compressors and of the titanium heat exchanger, ensures high performance and low energy consumption. The set of technologies used allows you to decrease noise levels and achieve the highest COP - coefficient of performance - contributing to significant energy savings. Digital Thermostat The setting of functions is intuitive and the temperature detection is accurate, resolution 0.5°C/1°F. The setting range is 5°-40°C (41°F-104°F) and there is a closed loop temperature control system with high accuracy and extremely tight differential 2°C/5°F. Displayed temperature is in °C or °F and there are security alarms. Possibility to control remotely the display using supplied cable, degree of protection IPX4. Efficient Design The chiller is characterized by a solid structure, designed to provide a perfect oxidation protection and therefore perfect for use with salt water Unique Features These units are also suitable for industrial applications and outdoor installation. Vertical ventilation ensures optimal operation even when working in harsh environments. Water temp. Ambient temp. Working mode Cooling Capacity COP** 25°C* 38°C Cooling 8,7KW 2,1 * The values reported in the table refer to the following conditions: heating load of 0.5 w/lt.** Coefficient of performance Power Supply Power Consumption Gas Weight Ambient temperature 50Hz - 3ph 4350W R410A 231,49 lb 5°C - 38°C All data are approximate and may be changed without notice by TECO.

    £10,939.15

  • TECO TK 5K commercial heat pump chiller/heater Commercial Chiller Teco

    Teco TECO TK 5K commercial heat pump chiller/heater

    The exclusive use of internationally recognized, high-performance rotary compressors and of the titanium heat exchanger, ensures high performance and low energy consumption. The set of technologies used allows you to decrease noise levels and achieve the highest COP - coefficient of performance - contributing to significant energy savings. Digital Thermostat The setting of functions is intuitive and the temperature detection is accurate, resolution 0.5°C/1°F. The setting range is 5°-40°C (41°F-104°F) and there is a closed loop temperature control system with high accuracy and extremely tight differential 2°C/5°F. Displayed temperature is in °C or °F and there are security alarms. Possibility to control remotely the display using supplied cable, degree of protection IPX4. Efficient Design The chiller is characterized by a solid structure, designed to provide a perfect oxidation protection and therefore perfect for use with salt water. Unique Features These units are also suitable for industrial applications and outdoor installation. Vertical ventilation ensures optimal operation even when working in harsh environments. Water temp. Ambient temp. Working mode Cooling Capacity COP** 25°C* 38°C Cooling 5,8KW 2,8 * The values reported in the table refer to the following conditions: heating load of 0.5 w/lt.** Coefficient of performance Power Supply Power Consumption Gas Weight Ambient temperature 50Hz - 1ph 2030W R410A 174,17 lb 5°C - 38°C All data are approximate and may be changed without notice by TECO.

    £7,727.78

  • Teco TK 3000 Aquarium Chiller 3,000 litre Commercial Chiller Teco

    Teco Teco TK 3000 Aquarium Chiller 3,000 litre

    The exclusive use of internationally recognised high-performance rotary compressors and of the titanium heat exchanger, ensures high performance and low energy consumption. The set of technologies used allows you to decrease noise levels and achieve the highest COP - coefficient of performance - contributing to remarkable energy savings. Digital Thermostat The setting of functions is intuitive and the temperature reading is accurate, resolution 0.1 °C/0.2°F. The setting range is 5°C - 35°C (41°F - 95°F) and the temperature is kept constant with a maximum differential of 0.5°C/1°F. Displayed temperature is in °C or °F and there are security alarms. Efficient Design The chiller is characterized by a solid structure designed to provide a perfect protection against oxidation and it is therefore perfect to be used with salt water. Unique Features These units are also suitable for industrial applications. The maintenance of the air filter is quick and easy. These units have the option of up to 4 x 400W heaters to be fitted, please ask for pricing Water temp. Liters US Gallons COP** 25°C* 3000 790 2,8 8°C** 500 210 1,4 * The values reported in the table refer to the following conditions: room temp. 30°C, heating load of 0.3 w/lt.** The values reported in the table refer to the following conditions: room temp. 30°C, heating load of 0.1 w/lt.*** Coefficient of performance. Power Supply Power Consumption Gas Weight Ambient temperature 50Hz 800W R410A 86 lb 5°C - 38°C All data are approximate and may be changed without notice by TECO

    £3,196.31

© 2024 GroAqua, Powered by Shopify

    • American Express
    • Apple Pay
    • Diners Club
    • Discover
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account