OxyGuard


  • OxyGuard Model 420 Dissolved Oxygen Probe Probe OxyGuard 4-20mA = 0-40mg/l (Super Saturated Water)

    OxyGuard OxyGuard Model 420 Dissolved Oxygen Probe

    The Model 420 is a membrane covered galvanic oxygen probe with built-in two-wire 4-20 mA transmitter. The probe is connected to a DC supply and draws a current of between 4 and 20 mA corresponding to the oxygen concentration.There are only two wires to connect, and there is no limit to cable length. The output signal is galvanically isolated from the built-in electronics and the process fluid. Interference between the Model 420 and other equipment can never occur! DescriptionThe Model 420 is a membrane covered galvanic oxygen probe with built-in two-wire 4-20 mA transmitter. The probe is connected to a DC supply and draws a current of between 4 and 20 mA corresponding to the oxygen concentration. There are only two wires to connect, and there is no limit to cable length. The output signal is galvanically isolated from the built-in electronics and the process fluid. Interference between the Model 420 and other equipment can never occur! The OxyGuard Model 420 can therefore be connected directly to a wide range of equipment that can accept a 4-20 mA input, such as alarms, indicators, controllers, recorders, PLC’s, PC systems with A/D input etc. The Model 420 can also be used to measure gaseous oxygen concentration Key BenefitsExtremely High Stability -zero adjustment is never needed, calibration seldom No regular maintenance needs. The robust membrane is easily cleaned, but if damaged can be easily replaced Correct measurements with flow as low as 1cm/s Based on a chemical principle superior to that of traditional DO probes Galvanic type - True Zero Built0in temperature compensation No practical limit to cable length Wide range of armatures and fixtures - e.g. the AirAlam for worker safety in areas where fluctuating oxygen levels could occur in the air D033 OxyGuard Model 420 DO Probe for 4-20mA

    £774.00 - £842.74

  • OxyGuard Ozone Sensor Probe OxyGuard High Range

    OxyGuard OxyGuard Ozone Sensor

    OxyGuard's developed ozone sensor is designed specifically for use in aquaculture. The sensor uses an entirely new innovative technology, and the partial pressure of ozone is measured directly without the use of electrolyte, reagents, light, or other traditional methods. As a result, there is almost no maintenance, the probe is exceptionally stable, and the response time is extremely fast.With the possibility to measure ozone content in the water down to only a few μg/L, it is possible to ensure safe conditions for the stock. Unit of Measurement: ppm (mg/l) Measuriing Range (Low): 0-0.8mg/l (best between 0 and 0.5) Mesauring Range (High): 0.5-8mg/l Operating Temperature: 0-40C Dimensions: 40 x 104mm Cable Legnth: 7m Response Time: 90% in less than 45s (for the low range type) Medium: Water Installation: For use with Pacific or Marlin G20 OxyGuard Ozone Sensor Data Sheet

    £1,324.80

  • OxyGuard Pacific DO Probe Probe OxyGuard

    OxyGuard OxyGuard Pacific DO Probe

    The OxyGuard Standard Probe – the probe that revolutionised oxygen monitoring.The probe that you can purchase today is even better than the probe introduced in 1987 that helped revolutionize fish farming and make modern aquaculture the industry it is today. Today’s OxyGuard Standard Probe is hermetically sealed. If needed you can open it to replace the membrane and renovate it completely, but this should not be needed for many years. DescriptionThe measurement stability of the OxyGuard Standard Probe is also very high indeed. A probe measuring in air will maintain accuracy even when subjected to a sudden 20 degree celcius temperature change. The sensitivity of a probe measuring in clean air at room temperature will remain the same for at least 3 years. This proves that the OxyGuard probe is not, like some other probes, affected by “ageing”. OxyGuard believe that the OxyGuard Standard probe is more accurate, needs less attention and maintenance and has a lower total cost of ownership than any other oxygen or dissolved oxygen probe offered to the aquaculture industry today. *Accessories are shipped with every OxyGuard probe. You will thus be able to change the membrane if you manage to damage it during installation. Otherwise the accessories can be enough for up to 5 years’ use.

    £563.29

  • Last stock! Oxyguard pH / Redox Probe Probe OxyGuard pH Flow Through Light Duty

    OxyGuard Oxyguard pH / Redox Probe

    These OxyGuard probes consist of an electrode and an impedance converter inside a two part housing held together by a threaded collar. There is extra sealing so that the connections at the top of the electrode remain dry even when the probe is completely submersed. The impedance converter immediately over the electrode eliminates electrical noise problems and permits the use of ordinary cable to connect the probe. Either light duty or heavy duty OxyGuard pH or redox electrodes with flange fittings can be used. There are three basic designs, one for free mounting, one with a 3/4″ tee for flow-through use, the third designed to be screwed into a pipe, flange or other suitable fixture. The probes can be ordered with a 1″ thread at the top of the top part for mounting purposes. OxyGuard also manufacture probes to customer specification, so please ask if you cannot use a standard design. As standard the probes have 7m cables. K01 OxyGuard Static pH / Redox Probe

    £429.20 - £779.20

  • Oxyguard pH Buffer Solution Calibration Solution OxyGuard pH 4

    OxyGuard Oxyguard pH Buffer Solution

    Oxyguard pH Buffer Solution for calibrating pH probes. pH 4 / pH 7 205ml / 500ml

    £16.80

  • Oxyguard Polaris C (Dissolved oxygen meter) Handheld Meter OxyGuard 3m

    OxyGuard Oxyguard Polaris C (Dissolved oxygen meter)

    Hand-held oxygen and temperature meter with NFC tags and Bluetooth technology for easy data transfer to Cobália (Cobalia usage is optional) The Polaris C meter is a high-performance, low-cost and almost maintenance-free meter for measuring dissolved oxygen and temperature. The meter is sturdy, easy to use and has an extensive longevity making it ideal for harsh conditions. Polaris C can store up to 2500 complete data sets, including time and date stamps. The logged data is stored in the meter or can be transferred to Cobália using Bluetooth.Scan the Cobália NFC tag of the tank and all data will be uploaded to your “digital farm”. Tank specific data assigned to the tags will be stored in Cobália for analyses on temporal variations, multivariable analyses on performance and for the generation of graphs. The meter has a built-in self-check of all hardware, automatic barometric pressure compensation and a notably short response time. With this meter, you get the high-quality associated with OxyGuard technology and a product that will serve you well for many years. Download Brochure

    £984.80 - £1,050.84

  • OxyGuard Pond Master for Dissolved Oxygen Static System OxyGuard

    OxyGuard OxyGuard Pond Master for Dissolved Oxygen

    Pond Master is specifically designed for monitoring and control of oxygen levels in aquaculture facilities such as shrimp farms, carp farms, and other installations with individual ponds. This unique instrument incorporates advanced technology with an attractive, compact design resulting in a combination of user-friendly operation, accuracy, low maintenance needs and affordability. Probe not included Download Brochure

    £1,298.14

  • Last stock! OxyGuard Portable CO2 Meter Handheld Meter OxyGuard Default Title

    OxyGuard OxyGuard Portable CO2 Meter

    The OxyGuard portable CO2 meter is a reliable and easy-to-use instrument that measures dissolved carbon dioxide in water. The OxyGuard portable CO2 meter is a reliable and easy-to-use instrument that measures dissolved carbon dioxide in water. The meter consists of a probe and a battery-powered transmitter. The latter has a display showing the CO2 concentration and an analog signal as output. The transmitter has an on/off switch, "slope" and "zero" adjustments. Battery charger (230V), calibration accessories and 3-m cable are included. A version with built-in data logger is available. Description Measures the CO2 gas pressure directly and is not affected by carbonates or other dissolved substances. It is therefore possible to achieve simple, continuous direct measurements of carbon dioxide in water that affects fish. Methods such as test kits, laboratory analysis and the detection of pH changes are subject to disturbance from the dissolved substances found in aquaculture water. The OxyGuard CO2 measures only the CO2 that affects the fish, which is the free dissolved CO2 gas. It is reliable and accurate. Calibration accessories pack includes beaker with stirrer and magnet; 75 g of pH conditioner with dosing spoon; 100 mL of calibration solution with dosing syringe; and adjustment screwdriver. Technical Data G03 OxyGuard Portable CO2 Analyzer

    £3,223.20

  • OxyGuard Probe for Model 840 and 810 (3 Wire Cable) Probe OxyGuard

    OxyGuard OxyGuard Probe for Model 840 and 810 (3 Wire Cable)

    The OxyGuard Standard Probe – the probe that revolutionised oxygen monitoring. The probe that you can purchase today is even better than the probe introduced in 1987 that helped revolutionize fish farming and make modern aquaculture the industry it is today.Today’s OxyGuard Standard Probe is hermetically sealed. If needed you can open it to replace the membrane and renovate it completely, but this should not be needed for many years. The measurement stability of the OxyGuard Standard Probe is also very high indeed. A probe measuring in air will maintain accuracy even when subjected to a sudden 20 degree celcius temperature change. The sensitivity of a probe measuring in clean air at room temperature will remain the same for at least 3 years. This proves that the OxyGuard probe is not, like some other probes, affected by “ageing”. OxyGuard believe that the OxyGuard Standard probe is more accurate, needs less attention and maintenance and has a lower total cost of ownership than any other oxygen or dissolved oxygen probe offered to the aquaculture industry today. *Accessories are shipped with every OxyGuard probe. You will thus be able to change the membrane if you manage to damage it during installation. Otherwise the accessories can be enough for up to 5 years’ use.

    £709.20

  • Last stock! OxyGuard Salinity Probe for 4-20mA Probe OxyGuard

    OxyGuard OxyGuard Salinity Probe for 4-20mA

    The OxyGuard Salinity Probe is specially designed for aquaculture use. Factory calibration and automatic temperature compensation make it very easy to use. It is found in two versions. One is a 3-wire 4-20 mA sensor – connect it to 24 VDC and the output varies between 4 and 20 mA according to the salinity. The other has data bus connection for use with OxyGuard Pacific. The probe is designed to be as trouble-free as possible, with features specially suited for aquacultural use. Inductive technology is used so that you don’t have to worry about deposits on the surface of the probe – all you have to do is ensure that the hole in the probe is open and relatively clean. The probe measures salinity according to the internationally agreed PSS-78 scale (Practical Salinity Scale 78).

    £849.60

  • Last stock! OxyGuard Salinity Probe for Pacific and Marlin Probe OxyGuard

    OxyGuard OxyGuard Salinity Probe for Pacific and Marlin

    The OxyGuard Salinity Probe is specially designed for aquaculture use. Factory calibration and automatic temperature compensation make it very easy to use. It is found in two versions. One is a 3-wire 4-20 mA sensor – connect it to 24 VDC and the output varies between 4 and 20 mA according to the salinity. The other has data bus connection for use with OxyGuard Pacific. The probe is designed to be as trouble-free as possible, with features specially suited for aquacultural use. Inductive technology is used so that you don’t have to worry about deposits on the surface of the probe – all you have to do is ensure that the hole in the probe is open and relatively clean. The probe measures salinity according to the internationally agreed PSS-78 scale (Practical Salinity Scale 78).

    £849.60

  • OxyGuard Standard DO Probe (2 Wire) Probe OxyGuard For mg/l

    OxyGuard OxyGuard Standard DO Probe (2 Wire)

    The OxyGuard Standard Probe – the probe that revolutionised oxygen monitoring. The probe that you can purchase today is even better than the probe introduced in 1987 that helped revolutionize fish farming and make modern aquaculture the industry it is today.Today’s OxyGuard Standard Probe is hermetically sealed. If needed you can open it to replace the membrane and renovate it completely, but this should not be needed for many years. The measurement stability of the OxyGuard Standard Probe is also very high indeed. A probe measuring in air will maintain accuracy even when subjected to a sudden 20 degree celcius temperature change. The sensitivity of a probe measuring in clean air at room temperature will remain the same for at least 3 years. This proves that the OxyGuard probe is not, like some other probes, affected by “ageing”. OxyGuard believe that the OxyGuard Standard probe is more accurate, needs less attention and maintenance and has a lower total cost of ownership than any other oxygen or dissolved oxygen probe offered to the aquaculture industry today. *Accessories are shipped with every OxyGuard probe. You will thus be able to change the membrane if you manage to damage it during installation. Otherwise the accessories can be enough for up to 5 years’ use.

    £481.20


© 2024 GroAqua, Powered by Shopify

    • American Express
    • Apple Pay
    • Diners Club
    • Discover
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account